Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Microbiol Spectr ; 10(5): e0225722, 2022 Oct 26.
Article in English | MEDLINE | ID: covidwho-2019797

ABSTRACT

As the COVID-19 pandemic continues, countries around the world are switching toward vaccinations and boosters to combat the pandemic. However, waning immunity against SARS-CoV-2 wild-type (WT) and variants have been widely reported. Booster vaccinations have shown to be able to increase immunological protection against new variants; however, the protection observed appears to decrease quickly over time suggesting a second booster shot may be appropriate. Moreover, heterogeneity and waning of the immune response at the individual level was observed suggesting a more personalized vaccination approach should be considered. To evaluate such a personalized strategy, it is important to have the ability to rapidly evaluate the level of neutralizing antibody (nAbs) response against variants at the individual level and ideally at a point of care setting. Here, we applied the recently developed cellulose pulled-down virus neutralization test (cpVNT) to rapidly assess individual nAb levels to WT and variants of concerns in response to booster vaccination. Our findings confirmed significant heterogeneity of nAb responses against a panel of SARS-CoV-2 variants, and indicated a strong increase in nAb response against variants of concern (VOCs) upon booster vaccination. For instance, the nAb response against current predominant omicron variant was observed with medians of 88.1% (n = 6, 95% CI = 73.2% to 96.2%) within 1-month postbooster and 70.7% (n = 22, 95% CI = 66.4% to 81.8%) 3 months postbooster. Our data show a point of care (POC) test focusing on nAb response levels against VOCs can guide decisions on the potential need for booster vaccinations at individual level. Importantly, it also suggests the current booster vaccines only give a transient protective response against some VOC and new more targeted formulations of a booster vaccine against specific VOC may need to be developed in the future. IMPORTANCE Vaccination against SARS-CoV-2 induces protection through production of neutralization antibodies (nAb). The level of nAb is a major indicator of immunity against SARS-CoV-2 infection. We developed a rapid point-of-care test that can monitor the nAb level from a drop of finger stick blood. Here, we have implemented the test to monitor individual nAb level against wild-type and variants of SARS-CoV-2 at various time points of vaccination, including post-second-dose vaccination and postbooster vaccination. Huge diversity of nAb levels were observed among individuals as well as increment in nAb levels especially against Omicron variant after booster vaccination. This study evaluated the performance of this point-of-care test for personalized nAb response tracking. It verifies the potential of using a rapid nAb test to guide future vaccination regimens at both the individual and population level.


Subject(s)
COVID-19 , Vaccines , Humans , SARS-CoV-2/genetics , Antibodies, Viral , Pandemics , COVID-19/prevention & control , Antibodies, Neutralizing , Vaccination
2.
Commun Med (Lond) ; 1: 46, 2021.
Article in English | MEDLINE | ID: covidwho-1860418

ABSTRACT

Background: Neutralizing antibodies (NAbs) prevent pathogens from infecting host cells. Detection of SARS-CoV-2 NAbs is critical to evaluate herd immunity and monitor vaccine efficacy against SARS-CoV-2, the virus that causes COVID-19. All currently available NAb tests are lab-based and time-intensive. Method: We develop a 10 min cellulose pull-down test to detect NAbs against SARS-CoV-2 from human plasma. The test evaluates the ability of antibodies to disrupt ACE2 receptor-RBD complex formation. The simple, portable, and rapid testing process relies on two key technologies: (i) the vertical-flow paper-based assay format and (ii) the rapid interaction of cellulose binding domain to cellulose paper. Results: Here we show the construction of a cellulose-based vertical-flow test. The developed test gives above 80% sensitivity and specificity and up to 93% accuracy as compared to two current lab-based methods using COVID-19 convalescent plasma. Conclusions: A rapid 10 min cellulose based test has been developed for detection of NAb against SARS-CoV-2. The test demonstrates comparable performance to the lab-based tests and can be used at Point-of-Care. Importantly, the approach used for this test can be easily extended to test RBD variants or to evaluate NAbs against other pathogens.

3.
Bioengineering & Translational Medicine ; 7(2), 2022.
Article in English | ProQuest Central | ID: covidwho-1848906

ABSTRACT

There is clinical need for a quantifiable point‐of‐care (PoC) SARS‐CoV‐2 neutralizing antibody (nAb) test that is adaptable with the pandemic's changing landscape. Here, we present a rapid and semi‐quantitative nAb test that uses finger stick or venous blood to assess the nAb response of vaccinated population against wild‐type (WT), alpha, beta, gamma, and delta variant RBDs. It captures a clinically relevant range of nAb levels, and effectively differentiates prevaccination, post first dose, and post second dose vaccination samples within 10 min. The data observed against alpha, beta, gamma, and delta variants agrees with published results evaluated in established serology tests. Finally, our test revealed a substantial reduction in nAb level for beta, gamma, and delta variants between early BNT162b2 vaccination group (within 3 months) and later vaccination group (post 3 months). This test is highly suited for PoC settings and provides an insightful nAb response in a postvaccinated population.

4.
Lab Chip ; 22(7): 1321-1332, 2022 03 29.
Article in English | MEDLINE | ID: covidwho-1713230

ABSTRACT

Surveillance of SARS-CoV-2 infection is critical for controlling the current pandemic. Antigen rapid tests (ARTs) provide a means for surveillance. Available lateral flow assay format ARTs rely heavily on nitrocellulose paper, raising challenges in supply shortage. Vertical flow assay (VFA) with cellulose paper as test material attracts much attention as a complementary test approach. However, current reported VFAs are facing challenges in reading the test signal from the bottom face of the test cassette, complicating the test workflow and hindering translation into rapid test application. Here, we address this gap with an enhanced VFA against SARS-CoV-2 N protein that adapts a cellulose pull-down test format allowing (1) one-step sample application at the top of the test cassette and (2) readout of the test signal from the top. We also demonstrate the feasibility of translating the enhanced VFA into a point-of-care application that can help in SARS-CoV-2 surveillance.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Humans , Pandemics , Point-of-Care Systems , Sensitivity and Specificity
5.
ACS Sens ; 7(2): 477-487, 2022 02 25.
Article in English | MEDLINE | ID: covidwho-1641831

ABSTRACT

The ongoing COVID-19 pandemic has emphasized the urgent need for rapid, accurate, and large-scale diagnostic tools. Next to this, the significance of serological tests (i.e., detection of SARS-CoV-2 antibodies) also became apparent for studying patients' immune status and past viral infection. In this work, we present a novel approach for not only measuring antibody levels but also profiling of binding kinetics of the complete polyclonal antibody response against the receptor binding domain (RBD) of SARS-CoV-2 spike protein, an aspect not possible to achieve with traditional serological tests. This fiber optic surface plasmon resonance (FO-SPR)-based label-free method was successfully accomplished in COVID-19 patient serum and, for the first time, directly in undiluted whole blood, omitting the need for any sample preparation. Notably, this bioassay (1) was on par with FO-SPR sandwich bioassays (traditionally regarded as more sensitive) in distinguishing COVID-19 from control samples, irrespective of the type of sample matrix, and (2) had a significantly shorter time-to-result of only 30 min compared to >1 or 4 h for the FO-SPR sandwich bioassay and the conventional ELISA, respectively. Finally, the label-free approach revealed that no direct correlation was present between antibody levels and their kinetic profiling in different COVID-19 patients, as another evidence to support previous hypothesis that antibody-binding kinetics against the antigen in patient blood might play a role in the COVID-19 severity. Taking all this into account, the presented work positions the FO-SPR technology at the forefront of other COVID-19 serological tests, with a huge potential toward other applications in need for quantification and kinetic profiling of antibodies.


Subject(s)
COVID-19 , Surface Plasmon Resonance , Antibodies, Viral , COVID-19/diagnosis , Humans , Pandemics , SARS-CoV-2 , Spike Glycoprotein, Coronavirus , Surface Plasmon Resonance/methods
6.
medrxiv; 2021.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2021.11.11.21266241

ABSTRACT

There is clinical need for a quantifiable point-of-care (PoC) SARS-CoV-2 neutralizing antibody (nAb) test that is adaptable with the pandemics changing landscape. Here, we present a rapid and semi-quantitative nAb test that uses finger stick or venous blood to assess the nAb response of vaccinated population against wild-type, alpha, beta, gamma, and delta variant receptor binding domains. It captures a clinically relevant range of nAb levels, and effectively differentiates pre-vaccination, post 1st dose and post 2nd dose vaccination samples within 10 minutes. The data observed against alpha, beta, gamma, and delta variants agrees with published results evaluated in established serology tests. Finally, our test revealed a substantial reduction in nAb level for beta, gamma, and delta variants between early BNT162b2 vaccination group (within 3 months) and later vaccination group (post 3 months). This test is highly suited for PoC settings and provides an insightful nAb response in a post-vaccinated population.

7.
Nanomaterials (Basel) ; 11(1)2021 Jan 13.
Article in English | MEDLINE | ID: covidwho-1389472

ABSTRACT

To date, surface plasmon resonance (SPR) biosensors have been exploited in numerous different contexts while continuously pushing boundaries in terms of improved sensitivity, specificity, portability and reusability. The latter has attracted attention as a viable alternative to disposable biosensors, also offering prospects for rapid screening of biomolecules or biomolecular interactions. In this context here, we developed an approach to successfully regenerate a fiber-optic (FO)-SPR surface when utilizing cobalt (II)-nitrilotriacetic acid (NTA) surface chemistry. To achieve this, we tested multiple regeneration conditions that can disrupt the NTA chelate on a surface fully saturated with His6-tagged antibody fragments (scFv-33H1F7) over ten regeneration cycles. The best surface regeneration was obtained when combining 100 mM EDTA, 500 mM imidazole and 0.5% SDS at pH 8.0 for 1 min with shaking at 150 rpm followed by washing with 0.5 M NaOH for 3 min. The true versatility of the established approach was proven by regenerating the NTA surface for ten cycles with three other model system bioreceptors, different in their size and structure: His6-tagged SARS-CoV-2 spike fragment (receptor binding domain, RBD), a red fluorescent protein (RFP) and protein origami carrying 4 RFPs (Tet12SN-RRRR). Enabling the removal of His6-tagged bioreceptors from NTA surfaces in a fast and cost-effective manner can have broad applications, spanning from the development of biosensors and various biopharmaceutical analyses to the synthesis of novel biomaterials.

8.
ACS Appl Mater Interfaces ; 13(33): 38990-39002, 2021 Aug 25.
Article in English | MEDLINE | ID: covidwho-1351922

ABSTRACT

The ongoing COVID-19 pandemic has clearly established how vital rapid, widely accessible diagnostic tests are in controlling infectious diseases and how difficult and slow it is to scale existing technologies. Here, we demonstrate the use of the rapid affinity pair identification via directed selection (RAPIDS) method to discover multiple affinity pairs for SARS-CoV-2 nucleocapsid protein (N-protein), a biomarker of COVID-19, from in vitro libraries in 10 weeks. The pair with the highest biomarker sensitivity was then integrated into a 10 min, vertical-flow cellulose paper test. Notably, the as-identified affinity proteins were compatible with a roll-to-roll printing process for large-scale manufacturing of tests. The test achieved 40 and 80 pM limits of detection in 1× phosphate-buffered saline (mock swab) and saliva matrices spiked with cell-culture-generated SARS-CoV-2 viruses and is also capable of detection of N-protein from characterized clinical swab samples. Hence, this work paves the way toward the mass production of cellulose paper-based assays which can address the shortages faced due to dependence on nitrocellulose and current manufacturing techniques. Further, the results reported herein indicate the promise of RAPIDS and engineered binder proteins for the timely and flexible development of clinically relevant diagnostic tests in response to emerging infectious diseases.


Subject(s)
Antigens, Viral/analysis , COVID-19 Serological Testing/methods , Nucleocapsid Proteins/analysis , SARS-CoV-2/chemistry , Biomarkers/analysis , Biosensing Techniques , COVID-19/prevention & control , Cellulose/chemistry , Enzyme-Linked Immunosorbent Assay/methods , Fluorescent Dyes/chemistry , Humans , Microfluidic Analytical Techniques/methods , Peptide Library , Protein Binding
9.
ACS Sens ; 6(5): 1891-1898, 2021 05 28.
Article in English | MEDLINE | ID: covidwho-1171743

ABSTRACT

Rapid and inexpensive serological tests for severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) antibodies are essential to conduct large-scale seroprevalence surveys and can potentially complement nucleic acid or antigen tests at the point of care. During the COVID-19 pandemic, extreme demand for traditional lateral flow tests has stressed manufacturing capacity and supply chains. Motivated by this limitation, we developed a SARS-CoV-2 antibody test using cellulose, an alternative membrane material, and a double-antigen sandwich format. Functionalized SARS-CoV-2 antigens were used as both capture and reporter binders, replacing the anti-human antibodies currently used in lateral flow tests. The test could provide enhanced sensitivity because it labels only antibodies against SARS-CoV-2 and the signal intensity is not diminished due to other human antibodies in serum. Three-dimensional channels in the assay were designed to have consistent flow rates and be easily manufactured by folding wax-printed paper. We demonstrated that this simple, vertical flow, cellulose-based assay could detect SARS-CoV-2 antibodies in clinical samples within 15 min, and the results were consistent with those from a laboratory, bead-based chemiluminescence immunoassay that was granted emergency use approval by the US FDA.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , Cellulose , Humans , Immunoassay , Pandemics , Sensitivity and Specificity , Seroepidemiologic Studies
10.
Aging (Albany NY) ; 12(19): 18878-18888, 2020 Oct 08.
Article in English | MEDLINE | ID: covidwho-841406

ABSTRACT

In this retrospective study we assessed the efficacy and safety of tocilizumab in patients with critical or severe coronavirus disease 2019 (COVID-19). We enrolled 181 patients admitted to Huoshenshan Hospital (Wuhan, China) with confirmed COVID-19 between January 2020 and February 2020. Ninety-two patients were treated with tocilizumab, and 89 patients were treated conventionally. We analyzed the clinical manifestations, changes in CT scan images, and laboratory tests before and after tocilizumab treatment, and compared these results with the conventionally treated group. A significant reduction in the level of C-reactive protein was observed 1 week after tocilizumab administration. In some cases this meant the end of the IL-6-related cytokine storm. In addition, tocilizumab relieved fever, cough, and shortness of breath with no reported adverse drug reactions. These findings suggest tocilizumab improves clinical outcomes and is effective for treatment of patients with critical or severe COVID-19. However, future clinical trials are needed to better understand the impact of tocilizumab interference with IL-6 and provide a therapeutic strategy for treatment of COVID-19.

SELECTION OF CITATIONS
SEARCH DETAIL